Maestría en Física Aplicada · 2022
Development of a linear diattenuation sensitive semi-autonomous and portable digital lensless holographic microscope
This document presents the development of a linear diattenuation sensitive, semi-autonomous and portable digital lensless holographic microscope (DLHM). With the development of this project, we aim to improve the performance of this microscopy technique and to broaden the possibilities for a portable DLHM device. We believe our microscope can potentially be used in the diagnosis of diseases. In order to address this aim, the following aspects were investigated within the scope of this project. i) The design of specialized illumination sources for DLHM that are efficient, mechanically stable, and easy to align. ii) The implementation of a DLHM sensitive to the linear diattenuation response of samples. iii) The study of machine-learning based autofocusing methods to be applied to DLHM holograms. iv) The design of specialized software to acquire and reconstruct DLHM holograms and iiv) the design and manufacture of proper mechanical couplings that integrate the DLHM setup with the cellphone’s digital sensor. Five papers and five proceedings are the resultant products of this thesis project. They constitute part of the core of this thesis and are attached by the end of the document.
Texto completo 131 páginas con texto
Leer la tesis completa Ficha en el repositorio
Contenido
- Abstractp. 86
- Theoretical framework & state of the artp. 11
- Sample close to source DLHM (SCS-DLHM)p. 12
- Problem statementp. 16
- Objectivesp. 17
- General objectivep. 17
- Specific objectivesp. 17
- microscopyp. 18
- Specialized illumination system for portable dlhmp. 19
- Portable DLHMp. 19
- FocusNET: An autofocusing learning-based model for dLHMp. 25
- DLHM Appp. 29
- General aspectsp. 29
- Backendp. 30
- Frontendp. 32
- User manualp. 32
- Conclusions and future workp. 34
- Acknoledgementsp. 36
- Referencesp. 37
- Published manuscriptsp. 42
- Manuscripts to be submittedp. 43
- Conference proceedingsp. 102
- Annexesp. 117
- Figure 1. Basic in-line digital lensless holographic microscope setupp. 13
- coherent wave-source and generating a magnified diffraction pattern of a Siphonapterap. 19
- Figure 4. Designed mechanical coupling for the pinhole based portable DLHMp. 22
- manufactured prototype of the portable freeform-based DLHMp. 23
- DLHMp. 77
- Figure 7. Classical autofocusing metrics for a DLHM hologramp. 26
- Figure 8. Flux diagram of the DLHM-Appp. 33