Bogotá - Ingeniería - Doctorado en Ingeniería - Ingeniería Química · 2023
Aerosol size distribution and size resolved composition in urban areas of Colombia
The Colombian Air Quality National Strategy have established that prevention actions, reduction, and control emissions should be focused mainly on particulate matter, PM10 and PM2.5, due to the consistent exceedances related to the air quality guidelines suggest by the World Health Organization and the Air Quality National Standard in urban areas. In addition, the harmful effects in public health of population exposed to airborne particles. Therefore, one of the aims of the Strategy is encouraging the scientific knowledge to improve the national air quality management. Therefore, the aim of this dissertation's is to further knowledge of particle size distribution (PSD) of aerosols in urban areas in Colombian, linking the local and regional sources of air pollutants and the local weather patterns. The study was conducted in two places of Colombia: Bogotá and Palmira (Cauca’s Valley). The airborne aerosols were investigated utilizing impactors cascades to measure the size of inhale particles. The particle number concentration and particle number size distribution were measured in the size range from 17 nm and 10 mm using an Electrical Low-Pressure Impactor (ELPI+). Also, was used an Andersen Non-viable Impactor Cascade to determinate the mass size distribution and collect samples size segregated in nine stages between 0.1 to 9 um, to determine the contained of organic carbon, elemental carbon, and water-soluble ions in airborne inhalable particles. The findings of this study revealed that Bogotá's urban background area had a higher average particle number concentration (3800 #/cm3) than the area that was most adversely affected by automobile emissions (2800 x103 #/cm3). The number particle size distribution was unimodal in the traffic station of “Las Ferias” with a diameter centered in 120 nm, which evidences the particles are formed and grow through atmospheric process. In other hand, the urban background area exhibited a bimodal distribution, with a larger mode centered in particles of 120 nm of diameter with a second mode centered in 30 nm of diameter, which is more relevant in morning rush traffic hours. The Lung Deposition Surface Area (LDSA) was estimated from the interaction between particle size distribution and the model of the particle deposition in the respiratory system published by the Commission on Radiological Protection (IRCP) (ICRP, 1994). In this study, the urban background area reveled higher concentrations than the area affected by traffic emissions in Bogota, and other similar environments reported in the scientific literature. The submicrometric particles PM1, which can enter the alveolar region of the human respiratory system, was 20.8 ug/m3 in Bogota and 13.8 ug/m3 in Palmira. The mass size distribution exhibits a bimodal distribution that is equally centered between 0.43 and 1.1 um and 4.7 and 9.0 um. According to the chemical composition size separated, elemental carbon was accumulated in the fine fraction of PM2.1 in Bogotá at a rate of 72%, relative to 57% in Palmira. On the other hand, organic carbon was more evenly distributed in fine and coarse fraction. The sulfate ion was one of the most abundant water-soluble ions in two sites, but the size distribution was different while in Palmira was mainly accumulated in fine mode, in Bogota was dispersed across the two-size fraction. (Texto tomado de la fuente)
Texto completo 198 páginas con texto
Leer la tesis completa Ficha en el repositorio
Contenido
- Introductionp. 17
- Electrical Low-Pressure Impactor (ELPI+) performance assessmentp. 23
- Introductionp. 17
- 1.1.1 The Electrical Low-Pressure Impactor (ELPI+)p. 25
- 1.1.2 The scanning mobility particle sizerp. 29
- 1.1.3 Comparisons of ELPI+ with other instrumentsp. 30
- Methodologyp. 33
- 1.2.1 Particle number concentration and size distribution assessmentp. 33
- 1.2.2 Particle number concentration assessmentp. 37
- Resultsp. 39
- 1.3.1 ELPI+ raw data examinationp. 39
- 1.3.2 Particle number concentrationsp. 40
- 1.3.3 Particle number size distributionp. 42
- 1.3.4 Volume particle size distributionp. 44
- 1.3.5 PM10 and PM2.5 mass concentrationp. 44
- Conclusionsp. 46
- Referencesp. 21
- Supplementary informationp. 51
- Ambient Particles in Urban Areas of Bogotá - Colombiap. 53
- Introductionp. 17
- Methodologyp. 33
- 2.1.1 Monitoring sitesp. 57
- 2.2.1. Particles number concentration and size distribution measurementp. 60
- 2.2.2. Lung Deposition Surface Areap. 61
- Resultsp. 39
- 2.3.1. Meteorological conditions at the study sitesp. 62
- 2.3.2. Particle Number Concentrationp. 63
- 2.3.3. Hourly variation of Particles Number Concentrationp. 64
- 2.3.4. Number Particle Size Distributionp. 66
- 2.3.5. Lung Deposited Area Surfacep. 69
- 2.3.6. Relationship between meteorological conditions and PNCp. 71
- Conclusionsp. 46
- Referencesp. 21
- Supplementary informationp. 51
- Colombian Urban Areasp. 85
- Introductionp. 17
- Experimentalp. 88
- 3.2.1. Sampling sitesp. 88
- 3.2.2. Meteorologyp. 89
- 3.2.3. Samplingp. 90
- 3.2.4. Mass size distributionp. 90
- 3.2.5. Chemical Analysisp. 91
- Results and discussionp. 92
- 3.3.1. Meteorology and transport patternsp. 92
- 3.3.2. Coarse and fine mass concentrations: PM9, PM2.1, PM1.1 and PM0.43p. 95
- 3.3.3. Mass size distributionp. 90
- 3.3.4. Chemical composition in fine and coarse particlesp. 99
- 3.3.5. Ion balancep. 104
- 3.3.6. Size distributions of chemical componentsp. 105
- 3.3.7. Correlation matrix of size-segregated chemical speciesp. 109
- 3.3.8. Characteristics of PM on the human respiratory systemp. 114
- 3.3.9. Chemical composition of breathily particlesp. 118
- Conclusionsp. 46
- Referencesp. 21
- Supplementary materialp. 129
- agro-industrial and urban emissionsp. 135
- Introductionp. 17
- Methodsp. 140
- 4.2.1. Description of the sampling sitep. 140
- 4.2.2. Sampling protocolsp. 142
- 4.2.3. Analytical methodsp. 143
- 4.2.4. Diagnostic ratios and mass closurep. 144
- Results and discussionsp. 151
- 4.3.1. Meteorologyp. 89
- 4.3.2. Bulk PM2.5 concentration and compositionp. 153
- 4.3.3. Ionsp. 155
- 4.3.4. Metalsp. 158
- 4.3.5. Carbohydratesp. 159
- 4.3.6. Polycyclic Aromatic Hydrocarbons (PAHs)p. 160
- 4.3.7. Alkanesp. 164
- 4.3.8. PM2.5 mass closurep. 166
- Conclusionsp. 46
- Referencesp. 21
- Supplementary informationp. 51
- Conclusions and Perspectivep. 193
- 5.1. Conclusionsp. 46
- 5.2. Perspectivesp. 196
- Table 1-1. Data sheet of cascade impactor in ELPI+ for each stagep. 25
- Table 1-2. Comparison of sampling instruments used in this studyp. 32
- 2012)p. 28
- Table 1-4. Operating parameters of ELPI+ during its intercomparison with SMPSp. 40
- Ferias and San Cristobal site in Bogotáp. 60
- September 11, and Sept 27 - October 11, 2017p. 63
- (21 – 119 nm) and TPC (21 nm – 10 m) and time of dayp. 74
- Table 4-1. Equations used to estimate the main components of PM2.5p. 145
- studyp. 79
- intercomparison with SMPS in Leibniz Institute for tropospheric researchp. 27
- used during the intercomparison with ELPI+p. 30
- (PNC) and Particle Number Size Distribution (PNSD)p. 33
- diameters assuming a = 1.6 g/cm3 and spherical ambient particlesp. 35
- measured with BAMp. 38
- diameterp. 51
- bluep. 42
- SMPS and grey solid line is PNSD by ELPI stagesp. 43
- SMPS and grey solid line is VNSD by ELPI+ stagesp. 44
- Quality Monitoring Networkp. 45
- diamonds)p. 46
- and particle mass size distribution. Source (Lefol et al., 2015)p. 54
- representative areas that surrounded Las Ferias station (C1) and San Cristobal (C2)p. 59
- aerodynamic diameter of each stage of ELPI+ (blue squares)p. 61