Sistema portable para la adquisición y procesamiento de señales ECG, con aplicabilidad en dispositivos móviles
The acquisition of electrocardiogram (ECG) signals is vital for diagnosing cardiovascular diseases, as it can reveal the actual state and conditions of the heart in patients under study. Currently, the fast advance of the electronic engineering had allowed the development of applications on the biomedicine field, implementing devices that allow bioelectrical signal acquisition and processing, leading to a specific and punctual monitorization of several organs of the human body. This makes easier, faster and better the medical procedures, improving the patients’ conditions during the medical interventions. In this project, a design of a portable system for ECG signal acquisition and processing, with applicability in mobile devices, is proposed, which is characterized principally for being a portable device that is easy to implement, both in the patient’s residences, as well as health care centers. The first step to develop the prototype is to build the electronic board based on the ADS1298 application-specific integrated circuit, by Texas Instruments Company, designed principally for ECG signals that counts with eight channels for data acquisition and a SPI communication port. The board works with the PIC32MX795F512H by the Microchip Company as the main processor of the system, which also has a SPI port for data transference between the ADS1298 and the PIC. The device programming is done through the MPLAB interface programming environment (MPLAB IPE), using libraries that were especially designed for the main code of the proposed device. Finally, a graphical user interface made in MATLAB® was implemented to display the recorded signals. The performed tests to validate the correct functionality of the ECG device shows that the planned development system has been accomplished, both in hardware and software. The needed requirements have been implemented in accordance with international rules of biomedical equipment. Finally, a device that registers twelve leads of ECG (Lead I, Lead II, Lead III, aVF, aVR, aVL, V1, V2, V3, V4, V5 y V6) has been obtained with a sample frequency of 250SPS, which can be visualized and registered in MATLAB®.
Texto completo 199 páginas con texto
Leer la tesis completa Ficha en el repositorio
Contenido
- RESUMENp. 17
- CAPITULO 1. INTRODUCCIÓNp. 20
- 1.1. Introducciónp. 20
- 1.2. Definición del problemap. 20
- 1.3. Justificaciónp. 22
- 1.4. Objetivosp. 24
- 1.4.1. Generalp. 24
- 1.1.1. Específicosp. 24
- 1.2. Metodologíap. 24
- 1.2.1. Etapa de investigación y fundamentaciónp. 25
- 1.2.2. Etapa de desarrollop. 26
- 1.2.3. Etapa de ejecuciónp. 26
- 1.2.4. Etapa de implementaciónp. 27
- 1.2.5. Etapa de resultadosp. 27
- CAPITULO 2. MARCO REFERENCIALp. 28
- 2.1. Marco teóricop. 29
- 2.1.1. Señales Biomédicasp. 29
- 2.1.2. Señales Bioeléctricasp. 29
- 2.1.3. Electrocardiograma (ECG)p. 30
- 2.1.4. Derivacionesp. 32
- 2.1.4.1. Derivaciones de plano frontalp. 33
- 2.1.4.1.1. Derivaciones bipolares clásicas del electrocardiogramap. 33
- 2.1.4.1.2. Derivaciones monopolares aumentadasp. 34
- 2.1.4.2. Derivaciones del plano horizontalp. 35
- 2.1.4.2.1. Derivaciones precordialesp. 36
- 2.1.5. Dispositivos de aplicación específica (ASIC’s)p. 37
- 2.1.5.1. Tipos de ASIC’s:p. 37
- 2.1.5.2. ASIC’s utilizados para mediciones ECG:p. 38
- 2.1.6. Filtro Antialiasingp. 39
- 2.1.6.1. Efecto Aliasingp. 40
- 2.1.6.2. Descripción Filtrop. 41
- 2.1.7. Interferencias de las señales electrocardiográficasp. 41
- 2.1.7.1. Filtros digitalesp. 42
- 2.1.7.2. Tipos de filtrosp. 42
- 2.1.8. Funcionamiento principal de un filtro digitalp. 45
- 2.1.9. Filtros digitales básicos para señales electrocardiográficasp. 46
- 2.1.10. Sistemas de adquisición de señales biomédicasp. 47
- 2.1.11. Amplificadores de biopotencialesp. 48
- 2.1.12. Norma internacional para equipos electromédicosp. 49
- 2.2. Marco históricop. 49
- 2.2.1. Historia del ECGp. 49
- 2.2.2. Origen de los ASIC’sp. 51
- CAPITULO 3. CAPTURA Y PROCESAMIENTO DE LA SEÑAL ECGp. 53
- 3.1. Consideraciones para el diseñop. 53
- 3.1.1. Matriz de necesidadesp. 53
- 3.1.2. Diagrama de Paretop. 54
- 3.2. Elección de materiales (electrodos y ASIC)p. 55
- 3.2.1. Integrado ADS1298p. 57
- 3.3. Elección del medio de transmisiónp. 59
- 3.3.1. PIC32MX795F512Hp. 61
- 3.4. Elección cable de pacientep. 63
- 3.5. Protección del pacientep. 65
- 3.6. Aislamiento del circuitop. 68
- 3.7. Alimentación del ADS1298p. 72
- 3.8. Puertos de comunicaciónp. 73
- 3.8.1. Bus de comunicación SPIp. 74
- 3.8.2. UARTp. 75
- 3.8.3. USBp. 62
- 3.9. Listado de componentesp. 78
- CAPITULO 4. DISEÑO DEL CIRCUITO DEL SISTEMA PORTABLEp. 80
- 4.1. Diagrama de bloques del esquema del circuitop. 80
- 4.1.2. Segunda etapa: Circuito del ADS1298p. 83
- 4.1.3. Tercera etapa: Fuentes de alimentación análogas para el ADS1298p. 85
- 4.1.4. Cuarta etapa: Circuito del PIC32MX795F512Hp. 87
- 4.1.5. Quinta etapa: Circuito de alimentaciónp. 89
- 4.2. Diseño del circuito físicop. 90
- CAPITULO 5. PRUEBAS PRELIMINARESp. 94
- 5.1. Conversión del dato binario a voltajep. 94
- 5.2. Visualización de resultados con diferentes pruebas en MATLAB®p. 97
- 5.2.1. Señal cuadradap. 97
- 5.2.2. Señal sinusoidalp. 99
- 5.3. Pruebas con ADS1298p. 101
- 5.3.1. Frecuencia de muestreo idealp. 101
- 5.3.2. Pruebas con señales externasp. 102
- 5.3.3. Ganancia idealp. 104
- 5.4. Filtros digitales desarrollados en MATLAB®p. 108
- CAPITULO 6. PROGRAMACIÓNp. 111
- 6.1. Inicializacionesp. 111
- 6.1.1. Definicionesp. 111
- 6.1.2. Variablesp. 113
- 6.1.3. Entradas y salidasp. 115
- 6.1.4. UARTp. 75
- 6.1.5. Serial Peripheral Interface (SPI)p. 116
- 6.1.6. Interrupcionesp. 120
- 6.1.7. Funciones para trabajar con el puerto SPIp. 122
- 6.1.8. Registros del ADS1298p. 124
- 6.2. Diagrama de flujop. 131
- 6.2.1. Función Complete_tramap. 132
- 6.2.1.1. Función crc16p. 134
- 6.2.2. Función SendDataBufferp. 135
- 6.2.3. Función interrupciónp. 136
- 6.2.3.1. Función ADS_updateDataCH8p. 137
- 6.2.3.2. Función ADS_updateDataCHxp. 139
- 6.2.3.3. Función de complemento a 2 (C2DATA)p. 140
- 6.3. Programación interfaz de usuario en MATLAB®p. 141
- CAPITULO 7. RESULTADOSp. 144
- 7.1. Conexión de electrodosp. 144
- 7.2. Puesta en funcionamiento del programap. 146
- 7.3. Gráficas de funcionamiento en tiempo realp. 148
- 7.3.1. Todas las derivaciones trazándose de manera óptimap. 148
- 7.3.2. Electrodo RA desconectadop. 149
- 7.3.3. Electrodo LA desconectadop. 150
- 7.3.4. Electrodo RL desconectadop. 150
- 7.3.5. Electrodo LL desconectadop. 151
- 7.3.6. Electrodo V1 desconectadop. 152
- 7.3.7. Electrodo V2 desconectadop. 152
- 7.3.8. Electrodo V3 desconectadop. 153
- 7.3.9. Electrodo V4 desconectadop. 153
- 7.3.10. Electrodo V5 desconectadop. 154
- 7.3.11. Electrodo V6 desconectadop. 154
- 7.3.12. Detección de error por CRC16p. 155
- 7.4. Comparación con graficas estándar del ECGp. 155
- 7.5. Costosp. 159
- CAPITULO 8. CONCLUSIONES E IMPACTO DEL PROYECTOp. 160
- 8.1. Conclusionesp. 160
- 8.2. Impacto del proyecto (salud, social, económico)p. 163
- 8.2.1. Impacto en saludp. 163
- 8.2.2. Impacto socialp. 163
- 8.2.3. Impacto económicop. 164
- BIBLIOGRAFIAp. 165
- ANEXOSp. 169
- Tabla 1. Guía para matriz de necesidadesp. 53
- Tabla 2. Evaluación de necesidadesp. 54
- Tabla 3. Matriz de necesidadesp. 54
- Tabla 4. ASIC para la captura de señales biomédicasp. 56
- Tabla 5. TABLA COMPARATIVA PICp. 60
- Tabla 6. Características PIC32MX795F512Hp. 62
- Tabla 7. Características integrado PESD5V0S2BTp. 66
- Tabla 8. Características integrado OPA376AIDCKTp. 68
- Tabla 9. Características integrado ADUM3160BRWZp. 69
- Tabla 10. Corrientes integrados principalesp. 70
- Tabla 11. características integrado NCM6S0505ECp. 71
- Tabla 12. Características fuentes de alimentaciónp. 72
- Tabla 13. Características integradoADM7154ARDZp. 73
- Tabla 14. Tabla de componentes completap. 78
- Tabla 15. Valores ideales del código de salidap. 94
- Tabla 16. Comparación de los valores de entrada vs el código de salidap. 95
- complemento a 2p. 96
- Tabla 18. Cantidad de bits en comunicación SPIp. 119
- Tabla 19. Valor Registro CONFIG3p. 125
- Tabla 20. Valor Registro CONFIG1p. 125
- Tabla 21. Valor Registro CONFIG2p. 126
- Tabla 22.Valor Registro CONFIG4p. 126
- Tabla 23. Valor Registro LOFFp. 127
- Tabla 24. Valor Registro LOFF_SENS(P/N)p. 127
- Tabla 25. Valor Registro RLD_SENS(P/N)p. 128
- Tabla 26. Valor Registro CHxSETp. 129
- Tabla 27. Valor Registro WCT1p. 131
- Tabla 28. Valor Registro WCT2p. 131
- Tabla 29. Paquetes de datos de lectura ADS1298p. 139
- Tabla 30. Costo total de fabricaciónp. 159
- Figura 1. Diseño metodológico generalp. 25
- Figura 2. Esquema general para el desarrollo del proyectop. 28
- Figura 3. Ondas de la señal ECGp. 31
- Figura 4. Triángulo de Einthovenp. 31
- Figura 5. Electrodos médicosp. 32
- Figura 6. Esquema de las derivaciones monopolaresp. 35
- Figura 7. Esquema de las derivaciones precordialesp. 36
- Figura 8. Tipos de filtrosp. 44
- Figura 9. Diagrama de bloques de un filtro digital tipo FIRp. 45
- Figura 10. Diagrama de bloques de un filtro digital tipo IIRp. 46
- Figura 11. Diagrama de sistema generalizado para la adquisición de biopotencialesp. 48
- Figura 12. Diagrama de Pareto: Necesidadesp. 55
- Figura 13. Integrado ADS1298p. 58
- Figura 14. PIC32MX795F512Hp. 62
- Figura 15. Conductor de 10 derivaciones tipo pinza fijap. 64
- Figura 16. Tipos de conectores para enlace cable - equipop. 64
- Figura 17. Tipos de conectores para derivacionesp. 64
- Figura 18. Cable de 10 conductores de derivación tipo presiónp. 65
- Figura 19. Encapsulado SOT32 integrado PESD5V0S2BTp. 67
- Figura 20. Símbolo integrado PESD5V0S2BTp. 67
- Figura 21. Integrado ADUM3160BRWZp. 69
- Figura 22. Integrado NCM6S0505ECp. 71
- Figura 23. Integrado ADM7154ARDZp. 73
- Figura 24. Configuración de un bus SPI con un dispositivo maestro y 3 esclavosp. 75
- Figura 25. Diagrama de bloques UARTp. 76
- Figura 26. Pines y conector estándar USBp. 77
- Figura 27. Circuito protección de pacientesp. 82
- Figura 28. Circuito ADS1298p. 84
- Figura 29. Fuentes de alimentación ADS1298p. 86
- Figura 30. Circuito PIC32MX795F512Hp. 87
- Figura 31. Circuito externo para programar PIC32MXp. 88
- Figura 32. Pines cableados externamente para la configuración del ADS1298p. 89
- Figura 33. Circuito alimentaciónp. 90
- Figura 34. PCB capa TOP y BOTTOMp. 91
- Figura 35. Placa entregada por Microcircuitosp. 92
- Figura 36. Placa terminadap. 93
- Figura 37. Valores análogos vs binariosp. 95
- Figura 38. Valores análogos vs datos binarios con complemento a 2p. 96
- Figura 39. Código para graficar la señal generada en MATLAB®p. 97
- Figura 40. Gráficas generadasp. 98
- Figura 41. Gráficas de los 4 canales en MATLAB®p. 99
- Figura 42. Señal de entrada al ADS1299 en osciloscopiop. 100
- Figura 43. Señal de medida con el ADS1299 y graficada en MATLAB®p. 100
- Figura 44. Circuito para la adquisición de datosp. 101
- Figura 45. Pruebas a diferentes frecuencias de muestreop. 102
- Figura 46. Señal triangular de 1Hz muestreadap. 103
- Figura 47. Señal triangular de 2Hz muestreadap. 103
- Figura 48. Señal triangular de 5Hz muestreadap. 104
- Figura 49. Señal ECG, G=1p. 105
- Figura 50. Señal ECG, G=2p. 105
- Figura 51. Señal ECG, G=3p. 106
- Figura 52. Señal ECG, G=4p. 106
- Figura 53. Señal ECG, G=6p. 107
- Figura 54. Señal ECG, G=8p. 107
- Figura 55. Señal ECG, G=12p. 108
- Figura 56. Filtro pasa bajas para eliminar ruidos por respiración en MATLAB®p. 109
- Figura 57. Filtro Notch en MATLAB®p. 109
- Figura 58. Filtro pasa altas para eliminar nivel DC en MATLAB®p. 110
- Figura 59. Registro SPIxCONp. 118