Maestría en Ingeniería Química · 2025
Application of Ozone-based oxidative processes (O3, O3/H2O2 & O3/UV) in the removal of antibiotics
Currently, the presence of organic pollutants in water bodies is a significant concern. This type of contamination is generated by various industrial, agricultural, and urban activities, and it has been linked to adverse effects, including endocrine disruption in fish and mammals. In addition, there is no extensive regulation that controls the introduction of many chemical substances into the water, implying that it is necessary to implement new control measures. Antibiotics, including azithromycin (AZT), cephalexin (CPX), and doxycycline (DOX) are drugs used against pathogenic microorganisms in animals and humans. However, because of their incomplete absorption during their metabolization, together with their extensive and continuous use, they have mainly been released into the environment, resulting in their presence in a variety of environmental matrices such as surface waters, sediments, and soils. In particular, AZT, CPX, and DOX are some of the most widely consumed antibiotics worldwide, and their presence in different water bodies has been reported. When antibiotics enter bodies of natural water, they can select for a range of microorganisms and induce the production of resistant bacterial strains, which, when in contact with living beings, can cause diseases that are not treatable with conventional antibiotics, thereby diminishing the ability to stop epidemics. For its part, advanced oxidation technologies (AOTs) are commonly applied to reduce the concentration of different toxic substances that cannot be eliminated using conventional water treatment processes, due to its demonstrated capacity to remove several biological and chemical pollutants. AOTs are characterized by the generation of the hydroxyl radicals (HO•), which can remove a high number of organic pollutants present in different water matrices. Ozonation is a technology widely used in the treatment of drinking water. During ozonation, pollutants can be oxidized by ozone (O3) and/or HO• formed from the natural decomposition of O3 in water. Besides, the removal of contaminants could be enhanced by activating O3 with other agents, such as hydrogen peroxide (H2O2), UV radiation, and ultrasound. This study presents the main results obtained after evaluating the use of O3, O3/H2O2, O3/UV, and O3/H2O2/UV in the removal of a mixture of AZT, CPX, and DOX in both deionized water and hospital wastewater. The results indicated that O3 is the primary agent responsible for removing contaminants. However, the O3/H2O2/UV treatment was the one that allowed a higher mineralization of the organic matter. Additionally, the findings indicated that the presence of ions, turbidity, and organic matter in the wastewater could limit the removal of the antibiotics. This research also involved optimizing certain reaction conditions, analyzing the extent of antibiotics elimination and the reduction of the organic matter present in the treated samples, monitoring the organic carbon, and considering the reaction kinetics. Finally, the project results promote the development of techniques that favor the conservation of water resources and the minimization of pollution. They also contribute to strengthening national scientific capacity and human capital formation.
Texto completo 47 páginas con texto
Leer la tesis completa Ficha en el repositorio
Contenido
- ABSTRACTp. 6
- PROBLEM STATEMENT & STATE OF ARTp. 8
- THEORETICAL FRAMEWORKp. 11
- 2.1. Antibioticsp. 11
- Advanced Oxidation Technologiesp. 14
- Ozonationp. 14
- RESEARCH QUESTION & OBJECTIVESp. 17
- 3.1. Research question:p. 17
- 3.2. Objectivesp. 17
- General Objectivep. 17
- Specific objectivesp. 17
- MATERIALS & METHODSp. 18
- Chemicals and solventsp. 18
- Analytic methodsp. 18
- Ozone-based experimentsp. 22
- Anions and mineralization analysisp. 22
- RESULTS AND DISCUSSIONSp. 23
- Preliminary resultsp. 23
- AZT, CPX, and DOX removal optimizationp. 24
- AZT, CPX, and DOX removal under optimized conditionsp. 28
- AZT, CPX, and DOX removal using O3/H2O2p. 29
- AZT, CPX, and DOX removal using O3/UV and O3/H2O2/UVp. 31
- Mechanism and reaction kinetics analysisp. 33
- AZT, CPX, and DOX removal using O3/H2O2/UV in hospital wastewaterp. 36
- Mineralization analysisp. 38
- CONCLUSIONSp. 40
- RECOMMENDATIONS & FUTURE RESEARCHp. 41
- ASSOCIATED PRODUCTSp. 42
- Acknowledgmentsp. 42
- REFERENCESp. 43
- Figure 1. Molecular structure of antibiotics a. azithromycin, b. cephalexin and c. doxycyclinep. 13
- antibiotic), solution pH 7.0, and temperature 25.0°C)p. 24
- Figure 5. Molecular behaviour as a function of the solution pH for a. AZT, b. CPX, and c. DOXp. 27
- (pollutants initial concentration 3.0 mg/L (1.0 mg/L per antibiotic) and temperature 25.0°C)p. 28
- mg/L per antibiotic), O3 initial concentration 0.75 mg/L, solution pH 8.0, and temperature 25.0°C)p. 30
- 0.75 mg/L, H2O2 initial concentration 0.13 mg/L, solution pH 8.0, and temperature 25.0°C)p. 32
- and temperature 25.0°C)p. 35
- pH 8.0, and temperature 25.0°C)p. 36
- 0.13 mg/L, solution pH 8.0, and temperature 25.0°C)p. 38
- mg/L, H2O2 initial concentration 0.13 mg/L, solution pH 8.0, and temperature 25.0°C)p. 39
- Table 1. Removal conditions using ozone-based process for the antibioticsp. 16
- concentration 3.0 mg/L (1.0 mg/L per antibiotic) and temperature 25.0°C)p. 25
- 0.13 mg/L, solution pH 8.0, and temperature 25.0°C)p. 36
- ozone-based technologiesp. 37