Medellín - Minas - Doctorado en Ingeniería - Sistemas Energéticos · 2023
Design and analysis of a multi-stage control for power multi-converters in a DC microgrid
Microgrids are designed to connect different types of ac and dc loads, which require robust power controllers to achieve efficient energy transfer. However, the effects of AC and DC disturbances on a single type of controller make achieving such stability in a microgrid a design challenge. Additionally, in multistage systems and loads where disturbances affect both upstream and downstream of the microgrid, these controllers demand greater robustness. This thesis presents an analysis of a sliding mode control (SMC) applied to a multistage microgrid with direct current (DC) and alternating current (AC) power converters. The goal was to implement sliding mode controllers for converters that supply constant power loads DC-DC and DC-AC. The controller was tested considering a unique sliding surface facing external disturbances, such as variations in the frequency of AC converters, sudden changes in upstream voltages, and constant power loads (CPL). Initially, the simple first-order controller was analyzed, then with a washout filter, and subsequently experimentally validated. Next, a second-order controller was analyzed. The influence on the response and stability of the gain values (k) of the controller's sliding surface was also studied. The results show that the controller is robust in terms of sensitivity to external disturbances and steady-state error. However, it was observed that there are limiting values for the sliding surface constant 'k,' where if 'k' is too low, deceleration occurs, and the response to disturbances is critical, and if it is too high, undesired overshoot occurs in the output voltage. This way, it was observed that it is possible to find a single controller that offers some robustness to typical disturbances in a microgrid with commercial voltages.
Full text 102 pages with text
Read the full thesis Record in the repository
Contents
- LIST OF FIGURESp. 10
- LIST OF TABLESp. 14
- 1. INTRODUCTIONp. 15
- 1.1 Microgridsp. 16
- 1.2 Buck Converterp. 17
- 1.3 Variable Structure Systems (VSS)p. 20
- 2. SLIDING MODE CONTROLp. 21
- 2.1 Mathematical descriptionp. 22
- 2.2 Chattering in power systemsp. 24
- 2.3 Higher Order Sliding Mode Controlp. 25
- Referencesp. 26
- 3.1 Introductionp. 15
- 3.2 Materials and Methodsp. 31
- 3.3. Resultsp. 39
- 3.4. Conclusionsp. 47
- Referencesp. 26
- ON A WASHOUT FILTER APPLIED TO MICROGRIDSp. 52
- 4.1 Introductionp. 15
- 4.2 Material and Methodsp. 55
- 4.3 Results and Analysisp. 64
- 4.4 Conclusionsp. 47
- Referencesp. 26
- BUCK CONVERTERS POWERING CONSTANT POWER LOADSp. 75
- 5.1 Introductionp. 15
- 5.2 Material and Methodsp. 55
- 5.3 Resultsp. 39
- 5.4 Conclusionsp. 47
- Referencesp. 26
- 6. FINAL CONCLUSIONSp. 101
- FIGURE 1.1. TOPOLOGIES OF MICROGRIDS ACCORDING FROM [1]p. 16
- FIGURE 1.2. BUCK CONVERTER WITH CIL AND CPL. SOURCE: [2]p. 18
- FIGURE 2.1. PHASE PORTRAIT BY UTKIN IN [11]p. 22
- FIGURE 2.2. SIGMOID PLOTS FOR THREE “A” FACTOR (OWN ELABORATION)p. 25
- FIGURE 2.3. SECOND ORDER SLIDING MODE CONTROL VECTORS [12]p. 26
- FIGURE 3.1. SIMPLIFIED POWER NETWORK FEEDING DIRECT CURRENT (DC) LOADSp. 32
- MODULATION (PWM) CONTROLLER USED FOR THE SIMULATIONp. 34
- FIGURE 3.4. DIAGRAM OF THE GLOBAL SYSTEM FOR THE SIMULATIONp. 35
- FOR LOADS CIL, CPL, AND CIL-CPLp. 40
- FIGURE 3.6. INDUCTOR CURRENTS FOR THE THREE LOADSp. 41
- FIGURE 3.7. BEHAVIOR OF THE SYSTEM FOR THE THREE LOADSp. 42
- FIGURE 3.8. BIFURCATION DIAGRAM OF VC VS Kp. 43
- FIGURE 3.9. BIFURCATION DIAGRAM OF THE ERROR VS. Kp. 44
- CONTROL SMC, AND SMC WITH WASHOUT FILTERp. 45
- CONTROLLERS: PID, SMC, AND SMC WITH WASHOUT FILTERp. 47
- FIGURE 4.1. SIMPLIFIED DC POWER NETWORKp. 56
- FIGURE 4.2. CIRCUIT MODEL OF THE BUCK POWER CONVERTERp. 56
- FIGURE 4.3. BLOCK DIAGRAM OF THE EXPERIMENTp. 57
- FIGURE 4.4. DIAGRAM OF THE GLOBAL SYSTEMp. 62
- TIME CONTROLp. 64
- REGULATION OF VCREF =20Vp. 65
- TESTp. 66
- FIGURE 4.8. OUTPUT VOLTAGE VC FOR THE EXPERIMENT TESTp. 66
- FIGURE 4.9. ERROR FOR THE REGULATION OF VARIOUS SIGNALSp. 67
- R=20.44 Ω TO R=40.092 Ωp. 68
- FIGURE 4.11. BIFURCATION DIAGRAM OF VC VS K FOR THE SIMULATION TESTp. 69
- FIGURE 4.12. BIFURCATION DIAGRAM OF VC VS K FOR THE EXPERIMENTAL TESTp. 69
- TESTp. 70
- FIGURE 5.1. DIAGRAM OF THE AC-DC MICROGRIDp. 79
- FIGURE 5.3. CIRCUIT MODEL OF THE BUCK CONNECTED TO THE CIL (R) AND CPL (P)p. 81
- FIGURE 5.4. PHASE PORTRAITS FOR THE THREE CONTROLLERS IN THE MGp. 84
- MAIN DC BUS, (B) AC BUS, (C) AC CPL, (D) DC BUS 2, AND (E) DC CPLp. 88
- FIGURE 5.7. VOLTAGE OF THE MAIN DC BUS AFTER A DISTURBANCE IN DC BUS 1p. 89
- K = 3, (C) K = 10, (D) K = 15, (E) K = 20, AND (F) K = 80p. 91
- VOLTAGE, (B) AC VOLTAGE, AND (C) CPL VOLTAGEp. 92
- VOLTAGE, (B) AC VOLTAGE, AND (C) CPL VOLTAGEp. 92
- (A) MAIN BUS, (B) DC BUS, AND (C) CPL BUSp. 93
- HZ. (A) MAIN DC BUS (B) AC BUS, (C) AC CPL, (D) DC BUS 2, AND (E) DC CPLp. 94
- VOLTAGE, (C) AC CPL VOLTAGE, (D) DC VOLTAGE, AND (E) DC CPL VOLTAGEp. 95
- DC VOLTAGE, AND (E) VOLTAGE DC CPLp. 96
- TABLE 3-1 PARAMETERS OF THE CIRCUIT USED IN THE DIRECT CURRENT (DC) TESTp. 35
- TABLE 4-1. PARAMETERS USED IN THE DC TESTp. 63
- TABLE 5.1. PARAMETERS FOR THE DC-DC BUCK CONVERTERp. 80
- TABLE 5.2. TIME ANALYSIS AFTER A DISTURBANCE ON MAIN DC BUSp. 89